Urban Wind CFD — Pedestrian Comfort Analysis
Assess wind comfort around buildings with browser CFD. Model massing, run Lawson comfort criteria, export a one-page report. No desktop CFD licence required.
Tall buildings change the wind at ground level, sometimes in ways that make a plaza unusable. The Lawson wind comfort criteria turn "it feels unpleasant" into a number: five categories from A through E, defined by the exceedance probability of a threshold wind speed, each tied to how long a person can comfortably occupy the space.
The workflow is deliberately accessible to architects rather than to CFD specialists. Draw or import the massing, set the approach flow and the atmospheric stability, mesh the domain around the buildings, and run. The result is a comfort map over the site plan with Lawson categories attached to each region — the deliverable a planning submission actually asks for.
The engineering behind the assessment is ordinary steady RANS: a finite-volume or lattice incompressible solve over a domain large enough to keep the far-field boundaries away from the structures, with appropriate ground and roof boundary conditions. The hard part is never the solver; it is domain size, mesh resolution near the ground, and choosing a reference wind speed that means something at pedestrian height.
Because this runs in a browser, the study loop is fast enough to be genuinely iterative — try three massing options, compare the comfort maps, keep the best. That iteration is the actual value of the tool; a single comfort study is a deliverable, but comparing options is the design decision.
What makes an urban wind study hard
Almost never the solver. Steady RANS over a domain with adequate far-field clearance is routine. What actually decides whether a study is defensible is the input: the approach-flow reference speed, the atmospheric stability class, and the terrain roughness. Those three set the profile that the buildings then perturb, and each one is usually a planning assumption rather than a measurement.
Mesh resolution near the ground is the other one. Pedestrian-height comfort is decided in the first few metres, and a mesh that is fine in the building cores and coarse at pavement level will produce a map that looks plausible and is wrong exactly where people walk.
Frequently asked questions
What are the Lawson wind comfort criteria?
A five-category scale (A comfortable to E unsafe) based on the percentage of time the wind speed at pedestrian height exceeds a threshold. Category A allows sitting, B standing, C walking, D only briefly, E is unsafe.
What reference wind speed should I use?
It depends on the standard you are assessed against — typically a 10 m reference height at a defined return period. The conversion to pedestrian height depends on the terrain roughness and the atmospheric stability, both of which should be set rather than defaulted.
Try it now
The page you are reading is a static, crawler-readable summary. The interactive tool runs in your browser — nothing is uploaded.
Open CFD Lab Back to home